New Construction LS3 – Build a Passive House, Single family house eco-Sustainable NZEB
Villa of prestige with no.2 Certifications in progress at the institutes of independent European PassivHaus (D) and the Agency Casaclima (BZ).
Located in the Town of S. A. Li Battiati via Scala di Betta in the province of Catania.
Part of a complex of 10 villas is designed for very low energy requirements, and production plants to renewable sources to make the Home Zero Energy NZEB
It is a building, fully-electric, CEI 64-8 Class 3 with a home automation system the advanced UNI EN 5252 class and with systems and systems to be fully integrated, from video intercom, IP monitoring, energy and climate and anti-intrusion systems and video surveillance.
Provided of VMC system, controlled ventilation with recuperator of high efficiency machines certified by the PHI in Germany, and integration with air-Conditioning System in all-air ducted.
The objectives of manufacturer is to achieve a building with high Comfort, Healthy and Energy Efficient . The villa is commercially attractive because of the independent certification that ensures the customer on the quality of the work.
THE CLIENT CONSTRUCTOR
Costruzioni Generali Spa
STUDY DESIGN AND D. L.
Architectural Project
Study Buuum - Piero Marcantoni
Energy Project
Sapienza& Partners - Ing Carmelo Sapienza
Consultant Passivhaus Casaclima
Sapienza& Partners - Ing Carmelo Sapienza
Project of Electrical System and Automation
Sapienza&Partners - Ing Carmelo Sapienza
Project Water And Sanitary System
Sapienza&Partners – P. E. Stefano Mazzotta
Project Ventilation and Climate
Sapienza&Partners – P. E. Stefano Mazzotta
The project of Water and sanitation
Sapienza&Partners – P. E. Stefano Mazzotta
CERTIFICATIONS
Casaclima GOLD - EN 2144
PassivHaus - ID 5570
CLASS A4 - NZEB
Features the Housing with High Efficiency
Type -Detached Villa
Location - S.A. Li Battiati - CATANIA Italy
Year of construction 2018-2020
The opaque walls U=0,19 W/m K
Structure in c.to the pillar, cellular concrete and insulation with Rock Wool 16cm
Base U= 0,29 W/K square meters
Roof U= 0.15 W/K square meters rock Wool 20cm
Frames Uf= 0,97 W/K sqm PVC, coplanar with the fore and sliding uplifting
Door Input Ud= 1.2 W/K square meters
Glazing Ug= 0,72 W/K sqm B. E. g=50%, triple glass argon spacer hot
Blower Door Tests n50<0,6
Systems VMC, Climate, Electrical, and home Automation
Plant Ventilation VMC central 650 mc/h
Plant VRF channeled to all-air
Heating
Cooling
ACS Domestic Hot Water Accumulation of 500 Liters with PdC and Solar Thermal
Photovoltaic 8 kW
Demand for heating: 10 kWh/sqm year PHPP
Heat load: 10 W/sqm
Primary energy : 79 kWh/sqm year
The demand for cooling: 12 kWh/sqm year PHPP
Summer heat load: 10 W/sqm